Products

Engineered HVAC Products

Five families, 32 products. Every unit is manufactured to order and quoted against your project specification.

Precision Engineered Airflow. Formed on fully automated CNC lines.

Ductwork Systems & Fabrication

Galvanized, black and stainless steel ducts from 0.7 to 4.0 mm, cut and folded on the Auto Duct Line III and plasma CNC, fabricated to SMACNA.

Central HVAC Units & Equipment

Air handling units, fan coils, package and condensing units built for tropical operation and made to order against project airflow and capacity.

Explore Central HVAC Units & Equipment
Fan Section Units

Fan Section Units

Airflow: Up to 120,000 CMH

Belt-driven centrifugal fans to 120,000 CMH, at a single or variable speed

Learn more
Fan Coil Units (FCUs)

Fan Coil Units (FCUs)

Airflow range: 200 – 6,000 CFM

200 to 6,000 CFM, exposed or concealed

Learn more
Vertical Package Units

Vertical Package Units

Capacity: 5 – 30 tons

5 to 30 tons, indoor or outdoor, standard or split

Learn more
Condensing Units

Condensing Units

Capacity: 5 – 50 TR standard, to 200 TR

5 to 50 TR standard, custom builds up to 200 TR

Learn more

Ductwork Systems & Fabrication

Galvanized, black and stainless steel ductwork fabricated on fully automated CNC lines, from 0.7 mm sheet to 4.0 mm fully welded.

Explore Ductwork Systems & Fabrication
Galvanized Steel Ducts

Galvanized Steel Ducts

Thickness: 0.7 – 1.5 mm

0.7 to 1.5 mm, formed on automated CNC lines to SMACNA

Learn more
Black Steel Ducts

Black Steel Ducts

Thickness: 1.25 – 4.0 mm

Fully welded up to 4.0 mm, for heat and smoke

Learn more
Stainless Steel Ducts

Stainless Steel Ducts

Material: High-grade stainless steel

Contamination-free airflow for zero-tolerance spaces

Learn more

Airflow Control & Duct Accessories

Fire and smoke dampers, volume control dampers, VAV boxes, sound attenuators and access doors — the safety and balancing layer of the system.

Explore Airflow Control & Duct Accessories
Fire & Smoke Dampers

Fire & Smoke Dampers

Fusible link: UL-listed, 165 °C

UL-listed fusible links to 165 °C, motorized for smoke control

Learn more
Volume Control Dampers (VCD)

Volume Control Dampers (VCD)

Control: Hand-set, electric or pneumatic

Rectangular or round, hand-set or motorized, gasket-sealed

Learn more
Pressure Relief Dampers

Pressure Relief Dampers

Function: Maintains pressure in pressurised zones

Counterweight-adjustable, 100 × 100 to 1000 × 1000 mm

Learn more
Sound Attenuators

Sound Attenuators

Certification: VDI 6022 Pt 1 & 3, DIN 1946 Pt 4, VDI 3802

Hygienic attenuation certified to VDI 6022 and DIN 1946

Learn more
Electric Duct Heaters

Electric Duct Heaters

Size: Any, fabricated to capacity

Any size, fabricated to the required capacity

Learn more
Access Doors

Access Doors

Seal: Foam gasket and cam locks, 100% airtight

Airtight, from 100 × 100 to 600 × 1000 mm

Learn more

Air Terminals & Distribution

Diffusers, grilles and louvers in extruded aluminium — the visible half of the system, where airflow performance meets architecture.

Explore Air Terminals & Distribution
Jet Diffusers

Jet Diffusers

Throw: 8 – 55 m

Long throw to 55 m, adjustable ±30°, sizes 200 to 350

Learn more
Linear Slot Diffusers

Linear Slot Diffusers

Slots: 1 – 6, 3/4" or 1"

1 to 6 slots of 3/4" or 1", single sections to 3,500 mm

Learn more
Linear Bar Grilles

Linear Bar Grilles

Free area: Up to 65%

Up to 65% free area, single lengths to 2,700 mm

Learn more
Supply Air Grilles

Supply Air Grilles

Deflection: Single or double

Single or double deflection, up to 70% free area

Learn more
Return Air Grilles

Return Air Grilles

Blades: Fixed, angled

Wall-mounted return, about 50% free area

Learn more
Sand Trap Louvers

Sand Trap Louvers

Principle: Two-row vertical channel labyrinth

Double-layer vertical blades that trap and discharge sand

Learn more
Door Louvers

Door Louvers

Material: Weatherproof extruded aluminium

Weatherproof fixed blades at 3/4" spacing

Learn more

Specialized & Environmental Solutions

Cleanroom laminar flow ceilings, HEPA terminal boxes and industrial air curtains — where contamination control and door isolation are the specification.

Explore Specialized & Environmental Solutions

Services

More Than Equipment

Design support before the order, manufacturing to the specification, and technical support after delivery — one partner from selection to service.

  1. Before the order

    Design & Consultation

    Engineering support for consultants and contractors from the first selection: each unit is sized against the project's own airflow, pressure and coil duty.

    • Equipment selection support
    • Coil sizing on AHRI-certified Unilab software
    • Shop drawings
    • BOQ review against the specification
    Certifications & standards
  2. In the factory

    Manufacturing

    Every order is built to its own specification, in our own factories, with quality built into the line rather than inspected at the end.

    • Three factories in Egypt, Oman and Libya — 8,600 m²
    • 600+ tons of sheet metal and 220+ AHUs a year
    • Coil and casing tests before dispatch, ductwork to SMACNA
    • Lead times confirmed with each quotation
  3. After delivery

    Technical Support & After-Sales

    Our responsibility does not end at delivery. Our factories in Oman and Libya were established to guarantee fast delivery and support across the Gulf and North Africa.

    • On-site commissioning support
    • Spare parts for the equipment we manufacture
    • Maintenance support through its service life
    • Regional support from Egypt, Oman and Libya

Let’s talk about your project.

Our engineering team is ready to answer your questions and support your project at every stage.